Command Reference — DimmerLink Native Tasmota Driver

All commands follow standard Tasmota conventions:

  • Commands are case-insensitive.
  • An optional device number suffix (1 to 4) selects which detected device to address. No suffix, or suffix 0, defaults to device 1.
  • Sending a command with no argument returns the current state without changing anything.
  • All commands return JSON responses.

The native driver uses the prefix Dl for all commands (different from the Berry driver's DimmerLink prefix).


DlDim — Set channel brightness

Syntax:

plaintext
DlDim[] [,]
Parameter Type Range Description
dev integer 1-4 Device number (optional; default = 1)
ch integer 1-4 Channel number (optional; default = 1)
level integer 0-100 Brightness in percent

Examples:

plaintext
DlDim 50            # Device 1, channel 1 to 50%
DlDim 75            # Device 1, channel 1 to 75%
DlDim 2,30          # Device 1, channel 2 to 30%
DlDim2 100          # Device 2, channel 1 to 100%
DlDim2 3,0          # Device 2, channel 3 to 0% (off)
DlDim               # Query — returns all channel levels for device 1

Response:

json
{"DlDim1":{"Ch1":50,"Ch2":30,"Ch3":0,"Ch4":0}}

The response always includes all channels for the addressed device.

Notes:

  • Level 0 turns the channel off. The device stores no memory of the previous level — re-enabling requires sending a new non-zero level.
  • Level values above 100 are silently clamped to 100 by the driver.
  • If the device returns a non-zero error code after the write, the driver logs it at DEBUG level but does not return an error to the caller.

DlCurve — Set dimming curve

Syntax:

plaintext
DlCurve[] [,]
Parameter Type Range Description
dev integer 1-4 Device number (optional; default = 1)
ch integer 1-4 Channel number (optional; default = 1)
curve integer 0-2 Curve: 0 = LINEAR, 1 = RMS, 2 = LOG

Examples:

plaintext
DlCurve 0           # Device 1, channel 1 to LINEAR
DlCurve 2           # Device 1, channel 1 to LOG
DlCurve 2,1         # Device 1, channel 2 to RMS
DlCurve2 1          # Device 2, channel 1 to RMS
DlCurve             # Query — returns all channel curves for device 1

Response:

json
{"DlCurve1":{"Ch1":"LINEAR","Ch2":"LOG","Ch3":"LINEAR","Ch4":"LINEAR"}}

Notes:

  • The curve setting is applied per channel and is independent between channels on the same device.
  • Curve values outside 0-2 are rejected; the command has no effect and returns the current state.
  • Curve changes take effect on the next brightness command. Setting a curve does not by itself change the output level.

See Dimming Curves Explained for detailed descriptions of each curve and load-type recommendations.


DlFade — Set fade transition time

Syntax:

plaintext
DlFade[] 
Parameter Type Range Description
dev integer 1-4 Device number (optional; default = 1)
value integer 0-255 Fade duration in units of 100ms

Examples:

plaintext
DlFade 0            # Instant change (no fade)
DlFade 10           # 1.0 second fade
DlFade 50           # 5.0 second fade
DlFade 255          # 25.5 second fade (maximum)
DlFade2 20          # Device 2: 2.0 second fade
DlFade              # Query — returns current fade value for device 1

Response:

json
{"DlFade":0}

Notes:

  • Fade is a device-level setting, not per-channel. All channels on a device use the same fade time.
  • The fade is implemented in the MCU hardware. Once a brightness change is written over I2C, the device internally ramps to the new level over the configured duration.
  • Fade time 0 means immediate change. Fade applies to all brightness writes including those from web UI sliders.

DlStatus — Show full device status

Syntax:

plaintext
DlStatus[]
Parameter Type Range Description
dev integer 1-4 Device number (optional; default = 1)

Examples:

plaintext
DlStatus            # Status of device 1
DlStatus2           # Status of device 2

Response:

json
{
  "DimmerLink1": {
    "Addr": "0x50",
    "Bus": 1,
    "Ready": true,
    "FW": 1,
    "ACFreq": 50,
    "Fade": 10,
    "Ch1": {"Level": 75, "Curve": "LOG"},
    "Ch2": {"Level": 30, "Curve": "RMS"},
    "Ch3": {"Level": 0, "Curve": "LINEAR"},
    "Ch4": {"Level": 0, "Curve": "LINEAR"},
    "Temperature": 42,
    "ThermalState": "NORMAL"
  }
}

The Temperature and ThermalState fields appear only if the MCU firmware has the temperature feature enabled. The LastError field appears only if the last I2C operation produced a non-zero error code:

json
{
  "DimmerLink1": {
    "Addr": "0x50",
    "Bus": 1,
    "Ready": true,
    "FW": 1,
    "ACFreq": 50,
    "Fade": 0,
    "Ch1": {"Level": 0, "Curve": "LINEAR"},
    "LastError": "0xFE"
  }
}

DlReset — Software reset

Syntax:

plaintext
DlReset[]
Parameter Type Range Description
dev integer 1-4 Device number (optional; default = 1)

Examples:

plaintext
DlReset             # Reset device 1
DlReset2            # Reset device 2

Response:

json
{"Command":"Done"}

Notes:

  • Writes 0x01 to the COMMAND register (0x01).
  • After reset, the device's ready flag is set to false. It is restored automatically by the next second-tick poll once the device reports READY status.
  • The reset reinitializes the MCU firmware, including triggering a new AC frequency calibration cycle. During calibration, brightness commands may be ignored or produce inconsistent results.

DlRecalibrate — Re-calibrate AC frequency

Syntax:

plaintext
DlRecalibrate[]
Parameter Type Range Description
dev integer 1-4 Device number (optional; default = 1)

Examples:

plaintext
DlRecalibrate       # Recalibrate device 1
DlRecalibrate2      # Recalibrate device 2

Response:

json
{"Command":"Done"}

Notes:

  • Writes 0x02 to the COMMAND register.
  • Triggers a new AC frequency measurement cycle. Useful if the mains frequency is reporting incorrectly, or after moving the device to a different AC supply.
  • The device sets READY = 0 during calibration. Normal operation resumes automatically after calibration completes (typically 1-2 seconds).
  • Unlike DlReset, recalibration does not reset channel levels or curve settings.

DlAddress — Change or query I2C address

Syntax:

plaintext
DlAddress[] []
Parameter Type Range Description
dev integer 1-4 Device number (optional; default = 1)
new_addr hex or decimal 0x08-0x77 New I2C address (optional; omit to query)

Examples:

plaintext
DlAddress           # Query current address of device 1
DlAddress 0x51      # Change device 1 address to 0x51
DlAddress2 0x52     # Change device 2 address to 0x52
DlAddress 81        # Change device 1 to decimal 81 (= 0x51)

Response (query):

json
{"DlAddress":"0x50"}

Response (after successful change):

json
{"DlAddress":"0x51"}

Notes:

  • The address is accepted in hexadecimal (with 0x or 0X prefix) or decimal.
  • After writing, the driver waits 50ms and reads the VERSION register from the new address to verify the change. If verification fails, the command returns an error, but the device hardware may have already changed — use DlStatus to check.
  • The new address is stored in the MCU's internal flash and persists through power cycles.
  • The old address becomes invalid immediately after the command succeeds.
  • Addresses 0x00-0x07 and 0x78-0x7F are rejected as reserved I2C addresses.

Full command table

Command Argument Device Channel Returns
DlDim[N] [ch,]level Optional Optional All channel levels
DlCurve[N] [ch,]curve Optional Optional All channel curves
DlFade[N] value Optional -- Current fade value
DlStatus[N] -- Optional -- Full device status
DlReset[N] -- Optional -- Done
DlRecalibrate[N] -- Optional -- Done
DlAddress[N] [new_addr] Optional -- Current or new address